Advertisement
3 way switch wiring power through switch lighting contactor wiring diagram rywowtont me rh rywowtont me at lighting 2, switching wiring dia 18 Creative 3, Switch Wiring Power Through Switch Galleries

18 Creative 3, Switch Wiring Power Through Switch Galleries

Related photos in this diagram:

Other recommended diagram ideas:

3, Switch Wiring Power Through Switch - The travelers run from the primary switch (sw1) to one set of terminals on the four manner (sw2) and from the second set to the tourists at the last 3 manner (sw3). The hot to the light is from the commonplace terminal of sw3 (spliced thru each transfer container). The hot from the electricity source connects to the common terminal of the first 3-manner transfer (sw1) and the impartial is spiced via (sb1) to the second three-manner transfer (sw2) thru the three cord cable (c2, that still includes the vacationers that join the two switches) wherein it's miles spliced thru (sb2) to the neutral terminal of the mild. The new from the commonplace terminal of the second one 3-way transfer (sw2) is connected to the new terminal of the mild.

The left of the photo (light grey background) is what i have installation so far. The proper is what's existing. I now understand there's no neutral to visit the everyday transfer from the three way switch since it gets used as hot. The energy, cable c1, joins the circuit at the mild fixture f1. Right here the impartial connects to the mild f1 and is spliced thru to light f2. The hot from the strength source is spliced through each fixtures and terminates at the not unusual terminal of sw1 thru cable c3.

The strength supply in this circuit enters the mild fixture wherein the neutral connects to the light and the recent is spliced via (thru cable c2) to the common terminal of the three-manner switch (sw2). The tourists among the switches are also spliced collectively within the light fixture. The energy to the mild is via the commonplace terminal of the three-manner switch sw1. The hot source is hooked up to the not unusual terminal of sw1. The impartial is spliced to the white cord feeding the first fixture, through cable c1,wherein it is spliced to the neutral of both lights. The vacationer wires from the 2 switches skip instantly thru the furnishings via cable c3.

The electricity for the circuit joins the light fixture f1 thru the cable c5. The impartial connects to the mild (lt1) and is spliced through to lt2 through the cable c4. The hot from the strength source is spliced through to the not unusual terminal of the switch (sw1) thru cable c1.