Legrand Pass, Seymour 15, 125-Volt Industrial-Grade Straight Plug - 12 gauge wire is a touch tougher to work with but i've in no way had a great deal of a trouble getting it attached to outlets. (Operating with the greater stiffness & bulk within the junction box is the problem i have commonly noticed.) However, perhaps you can choose up a few 20 amp receptacles, even in case you don't anticipate using any 20a appliances? Glaringly a 20a receptacle needs to help 12ga wiring.

Exception no. 1: tap conductors shall have an ampacity sufficient for the weight served. Further, they shall have an ampacity of no longer less than 15 for circuits rated less than 40 amperes and not much less than 20 for circuits rated at forty or 50 amperes and simplest wherein these faucet conductors supply any of the following masses: (a) person lampholders or luminaires with faucets extending no longer longer than 450 mm (18 in.) Past any portion of the lampholder or luminaire. (B) a luminaire having tap conductors as supplied in 410.117. (C) person stores, other than receptacle outlets, with taps no longer over 450 mm (18 in.) Lengthy. (D) infrared lamp business heating home equipment. (E) nonheating leads of deicing and snow-melting cables and mats.

In case you are setting 15 amp receptacles on a 20 amp circuit with 12 gauge cord, then you definitely need to use the screw terminals, no longer the again stab terminals. I wouldn't use the ones in spite of 14 gauge twine as i have visible the wires bend and damage proper at the factor in which the protective become stripped and the plug is going dead or the breaker trips. Simply use the side terminals. Ensure that the wires are wrapped clockwise across the screw so that tightening the screws pulls the cord tighter and not so it's pushing the cord out.

Thanks to your hobby on this question. As it has attracted low-first-rate or junk mail solutions that needed to be eliminated, posting an answer now requires 10 recognition on this website (the affiliation bonus does no longer be counted). Could you want to answer this kind of unanswered questions as a substitute?. Whether or no longer i may want to get away with it, i would first off in no way placed 15a receptacles on a 20a line. I've in my opinion witnessed a receptacle soften on this fashion whilst a ten a heater on a 15a line cooked a 10a outlet. Identical precept applies to a 15a outlet on a 20a line. Very unsafe.